Techne Refrigerated Bath with TD10 Thermoregulator Lab Chillers FREE SHIPPING!!!

Techne Refrigerated Bath with TD10 Thermoregulator Lab Chillers FREE SHIPPING!!!

$995 (USD)

Providence, RI

orCall 1 (401) 965-5557

Description

This is a Techne Refrigerated Bath with TD10 Thermoregulator Lab Chillers in good running condition!


We have 8 in stock, see details below... comes complete, ready to work! FREE SHIPPING!!! Model # FRB5S Serial #107659-12 120 V 50-60 Hz 8 Amp 1000 Watts Model #FTE10DT Serial #107651-9 120 V 50-60 Hz 9 Amp 1000 Watts Techne TE-10D Tempunit Refrigerated Baths Techne refrigerated baths offer a completely integrated refrigerated circulating system for open or closed applications, with a temperature range from -35°C to +100°C. Each bath is supplied with a lid and bridging plate. Temperature control is via one of the four Techne thermoregulators, providing a choice of 12 different bath and thermoregulator combinations. Models There are three bath capacities available: • 7 litre (RB-5A) • 12 litre (RB-12A) • 22 litre (RB-22A) Features • Circulating bath with integrated refrigeration unit. • Temperature range from -35°C to +100°C. • Robust stainless-steel construction. • Three models of refrigerated bath available: 7, 12, 22 litre. • Four models of thermoregulators available (ordered seperately). • 3 year warranty. Technical Specification Cooling (at 20°C ambient) RB-5A RB-12A RB-22A Minimum achievable temperature¹ –20°C –35°C –30°C Cooling capacity at 20°C (W) 145 240 240 Cooling capacity at 0°C (W) 145 240 240 Cooling capacity at –10°C (W) 110 230 220 Internal coolant (not user accessible) - RB-5A (-20 degrees C) mixture of 50% water, 50% antifreeze. - RB-12A (-35 degrees C) mixture of 40% water, 40% antifreeze, 20% alcohol. - RB-22A (-30 degrees C) mixture of 40% water, 40% antifreeze, 20% alcohol. Recommended bath liquid - Techne low temperature bath oil (click here) Ordering Information Product Code Description FRB5D RB-5A bath, 7 litre capacity with refrigeration unit, - 20°C to 100°C (230V, 50-60Hz) FRB5P RB-5A bath, 7 litre capacity with refrigeration unit, - 20°C to 100°C (120V, 50-50Hz) FRB2D RB-12A bath, 12 litre capacity with refrigeration unit, - 35°C to 100°C (230V, 50-50Hz) FRB2P RB-12A bath, 12 litre capacity with refrigeration unit, - 35°C to 100°C (120V, 50-50Hz) FRB22D RB-22A bath, 22 litre capacity with refrigeration unit, - 30°C to 100°C (230V, 50-50Hz) FRB22P RB-22A bath, 22 litre capacity with refrigeration unit, - 30°C to 100°C (120V, 50-50Hz) FBCAL7PH Probe holder for RB-5A TE-10D Techne® invented the "Clip On" thermoregulator in 1948, and now offer four units. Thermoregulators are designed to be used with the Techne® unheated water baths or any other suitable laboratory vessels. They will heat, circulate and safely control the temperature of the liquid in the bath within precise limits. • Temperature range of -40°C to 120°C • Please note for sub-ambient cooling a Dip Cooler or Flow Cooler is required. Click here. • Applications <0°C and >100°C require Techne bath oil. Click here. • Excellent temperature stability: ±0.01°C at 40°C • 4 digit setting with a bright LED digital temperature display • Suitable for most routine laboratory applications • User adjustable over-temperature cut-out • Low liquid level cut-out as standard Sub-ambient cooling This thermoregulator can be used for sub-ambient cooling, right down to -40°C, although a low-temperature liquid is required below 0°C. Sub-ambient cooling can be achieved using the cooling coil accessory (part number FCC01) connected to an external chilling system, for example a cold tap. Alternatively a Techne dip-cooler or flow cooler could be used as a method of chilling. External circulation This thermoregulator can be used in several ways. (1) Stand-alone waterbath temperature controller with precision accuracy and stirring action. (2) Pump for recirculating chilled liquid produced in an external chiller allowing sub-ambient water bath temperature. (3) Pump for providing temperature control to an external system or device. (4) A combination of using externally chilled liquid and providing temperature control to an external system. For additional information, please see Application notes under "Downloads". Technical Specification Specifications to DIN 12876 TE-10D Temperature range* -40°C to +120°C Temperature selec tion Digital Temperature stability using water @ 40°C ±0.01°C Method of control PID Temperature sensor PRT Adjustable over-temperature cut-out Yes Low liquid level cut-out Yes Pump capacity litresminute 10 Pump capacity (mbar) 145 Nominal heater power at 120V (W) 1000 Nominal heater power at 240V (W) 1000 Extension below base (mm) 145 Dimensions L x W x H (mm) 237 x 124 x 260 Shipping weight 3.9kg Product Code Description FTE10DDC TE-10D digital thermoregulator, supplied with clamp (230V) FTE10DPC TE-10D digital thermoregulator, supplied with clamp (120V) Palm Tree #LR-0000-01202020GD-3 Pic# 01152020 Bid with Confidence on this item, check our feedback!!! * All information deemed accurate but may vary from model to model. Contact Larry for any questions you may have. Contact us at Four Zero One - Nine Six Five - Five Five Five Seven or Contact us through ebay Google "Larry Razza" to see more information & videos of our equipment! L R Associates, Inc. / Palm Tree Specialties ebay store Rhode Island, USA ___________________________________________________ Equipment Financing Available, please contact us! Fast Application, it’s all filled in for you... Online leasing applications (get LOW monthly payments) * Please Note: Not all machines may qualify for Leasing. Payments: We accept all Major Credit Cards, Bank Wires, Company and Personal Checks. SHIPPING: Contact us for great rates on shipping... We always get better rates... Please email us for a rigging and shipping quote; just include the zip code when inquiring and if you have a loading dock or ground level with forklift. Thank you! Contact us at Four Zero One - Nine Six Five - Five Five Five Seven or Contact us through ebay Message We also ship worldwide. CONDITIONS: All quotations are for immediate acceptance. They are subject to withdrawal, change and prior sale without notice. Shipping dates are only approximate and contingent upon delays beyond our control. All orders received are binding only when they have been accepted and acknowledged by us in writing. Provisions in customer’s purchase orders contrary to these conditions shall not be binding upon us unless accepted in writing. Unless otherwise specified, prices quoted are F.O.B. shipping point, exclusive of State, County and Federal taxes which must be added where applicable. Insurance on shipment must be requested by email, there will be an additional charge for shipping insurance. Any damage from shipping is the responsibility of the carrier and will be subject to the scrutiny of the carriers insurance company. Insurance claims paid by carrier's insurance will be paid according to time involved in settling the claim. Shipping destination must be available to receive the shipment… any costs incurred on delays due to the buyers’ destination being unable to receive the shipment and/or additional services required, will be the responsibility of the buyer. Care is taken to give reliable specifications, but these are not guaranteed. We reserve the right to correct typographical errors. All used equipment is sold "as is". INDEMNIFICATION: Used Machines may not incorporate approved activating mechanisms, operator safety devices or safety guards as required by OSHA or otherwise. It is the user's responsibility that the said machines be so equipped and safeguarded to meet OSHA and any other requirements before placing such machinery into operation. User agrees to indemnify and hold Seller harmless of and from any and all claims or liabilities from accidents involving these machines caused by failure of user, his employees, or agent to follow instructions, warnings, or recommendations furnished by manufacturer, or Seller, or by failure of user to comply with Federal, State and Local laws applicable to such equipment including the Occupational Safety and Health Act of 1970. User shall notify Seller promptly after occurrence of any accident involving these machines, and shall cooperate fully with Seller. or Seller's agent in investigating and determining the cause of said accident.

Specifications

ManufacturerTechne
ModelModel number 1: FRB5S Model number 2: FTE10DT
ConditionUsed
Serial NumberSerial number 1:107659-12 Serial number 2: 107651-9